Anaerobic Threshold Approximation with Minimum Number of Blood Samples
dc.contributor.author | Štork, Milan | |
dc.contributor.author | Novák, Jaroslav | |
dc.date.accessioned | 2023-01-23T11:00:18Z | |
dc.date.available | 2023-01-23T11:00:18Z | |
dc.date.issued | 2022 | |
dc.description.abstract-translated | In this paper the anaerobic threshold measuring and approximation with minimum number of blood samples is described. Anaerobic thresholds are calculated for athletes tested on a bicycle ergometer and treadmill ergometer where the heart rate and pulmonary ventilation parameters, oxygen consumption and carbon dioxide expenditure are continuously measured. The main goal of the paper is the possibility of minimizing the number of blood sampling for lactate measurements from which the lactate curve and anaerobic threshold can be estimated. | en |
dc.format | 4 s. | cs |
dc.format.mimetype | application/pdf | |
dc.identifier.citation | ŠTORK, M. NOVÁK, J. Anaerobic Threshold Approximation with Minimum Number of Blood Samples. In International Conference on Applied Electronics (AE 2022) : /proceedings/. Pilsen: University of West Bohemia, 2022. s. 157-160. ISBN: 978-1-66549-481-6 , ISSN: 1803-7232 | cs |
dc.identifier.doi | 10.1109/AE54730.2022.9920050 | |
dc.identifier.isbn | 978-1-66549-481-6 | |
dc.identifier.issn | 1803-7232 | |
dc.identifier.obd | 43937148 | |
dc.identifier.uri | 2-s2.0-85140884207 | |
dc.identifier.uri | http://hdl.handle.net/11025/51029 | |
dc.language.iso | en | en |
dc.project.ID | EF18_069/0009855/Elektrotechnické technologie s vysokým podílem vestavěné inteligence | cs |
dc.project.ID | SGS-2018-001/Výzkum a vývoj elektronických a komunikačních systémů ve vědeckých a inženýrských aplikacích | cs |
dc.project.ID | SGS-2021-005/Výzkum, vývoj a implementace moderních elektronických a informačních systémů | cs |
dc.publisher | IEEE | en |
dc.relation.ispartofseries | International Conference on Applied Electronics (AE 2022) : /proceedings/ | en |
dc.rights | Plný text je přístupný v rámci univerzity přihlášeným uživatelům. | cs |
dc.rights | © IEEE | en |
dc.rights.access | restrictedAccess | en |
dc.subject.translated | anaerobic threshold | en |
dc.subject.translated | bicycle egometer | en |
dc.subject.translated | curve fitting | en |
dc.subject.translated | invasive lactate measuring | en |
dc.subject.translated | lactate curve | en |
dc.subject.translated | lactate estimation | en |
dc.subject.translated | treadmill | en |
dc.title | Anaerobic Threshold Approximation with Minimum Number of Blood Samples | en |
dc.type | konferenční příspěvek | cs |
dc.type | ConferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
Files
Original bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- Stork_Anaerobic_Threshold_Approximation_with_Minimum_Number_of_Blood_Samples.pdf
- Size:
- 824.09 KB
- Format:
- Adobe Portable Document Format