Transition radiation measurements with a Si and a GaAs pixel sensor on a Timepix3 chip

dc.contributor.authorDachs, F.
dc.contributor.authorAlozy, J.
dc.contributor.authorBelyaev, N.
dc.contributor.authorBergmann, B. L.
dc.contributor.authorBeuzekom, M. van
dc.contributor.authorBilloud, T. R. V.
dc.contributor.authorBurian, Petr
dc.contributor.authorBroulím, Pavel
dc.contributor.authorCampbell, M.
dc.contributor.authorChelkov, G.
dc.contributor.authorCherry, M.
dc.contributor.authorDoronin, S.
dc.contributor.authorFilippov, K.
dc.contributor.authorFusco, P.
dc.contributor.authorGargano, F.
dc.contributor.authorHeijden, B. van der
dc.contributor.authorHeijne, E. H. N.
dc.contributor.authorKonovalov, S.
dc.contributor.authorCudie, X. L.
dc.contributor.authorLoparco, F.
dc.contributor.authorMascagna, V.
dc.contributor.authorMazziotta, M. N.
dc.contributor.authorMeduna, L.
dc.contributor.authorPernegger, H.
dc.contributor.authorPonomarenko, D.
dc.contributor.authorPospíšil, S.
dc.contributor.authorPrest, M.
dc.contributor.authorRembser, C.
dc.contributor.authorRomaniouk, A.
dc.contributor.authorSavchenko, A. A.
dc.contributor.authorSchaefer, D.
dc.contributor.authorSchioppa, E. J.
dc.contributor.authorSergeeva, D.
dc.contributor.authorShchukin, D.
dc.contributor.authorShulga, E.
dc.contributor.authorSmirnov, S.
dc.contributor.authorSmirnov, Y.
dc.contributor.authorSmolyanskiy, P.
dc.contributor.authorSoldani, M.
dc.contributor.authorSpinelli, P.
dc.contributor.authorStrikhanov, M.
dc.contributor.authorTeterin, P.
dc.contributor.authorTikhomirov, V.
dc.contributor.authorTishchenko, A.A.
dc.contributor.authorVallazza, E.
dc.contributor.authorVorobev, K.
dc.contributor.authorZhukov, K.
dc.date.accessioned2020-09-07T10:00:13Z
dc.date.available2020-09-07T10:00:13Z
dc.date.issued2020
dc.description.abstract-translatedGrowing energies of particles at modern or planned particle accelerator experiments as well as cosmic rayexperiments require particle identification at gamma-factors (𝛾) of up to∼105. At present there are no detectorscapable of identifying charged particles with reliable efficiency in this range of𝛾. New developments in highgranular pixel detectors allow one to perform simultaneous measurements of the energies and the emissionangles of generated transition radiation (TR) X-rays and use the maximum available information to identifyparticles. First results of studies of TR energy-angular distributions using gallium arsenide (GaAs) sensorsbonded to Timepix3 chips are presented. The results are compared with those obtained using a silicon (Si)sensor of the same thickness of 500μm. The analysis techniques used for these experiments are discussed.en
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.identifier.citationDACHS, F., ALOZY, J., BELYAEV, N., BERGMANN, BL., BEUZEKOM, MV., BILLOUD, TRV., BURIAN, P., BROULÍM, P., CAMPBELL, M., CHELKOV, G., CHERRY, M., DORONIN, S., FILIPPOV, K., FUSCO, P., GARGANO, F., HEIJDEN, BVD., HEIJNE, EHN., KONOVALOV, S., CUDIE, XL., LOPARCO, F., MASCAGNA, V., MAZZIOTTA, MN., MEDUNA, L., PERNEGGER, H., PONOMARENKO, D., POSPÍŠIL, S., PREST, M., REMBSER, C., ROMANIOUK, A., SAVCHENKO, AA., SCHAEFER, D., SCHIOPPA, EJ., SERGEEVA, D., SHCHUKIN, D., SHULGA, E., SMIRNOV, S., SMIRNOV, Y., SMOLYANSKIY, P., SOLDANI, M., SPINELLI, P., STRIKHANOV, M., TETERIN, P., TIKHOMIROV, V., TISHCHENKO, A., VALLAZZA, E., VOROBEV, K., ZHUKOV, K. Transition radiation measurements with a Si and a GaAs pixel sensor on a Timepix3 chip. Nuclear Instruments and Methods in Physics Research, A, 2020, roč. 958, č. 1. April 2020, s. 1-4. ISSN 0168-9002.en
dc.identifier.document-number514843900151
dc.identifier.doi10.1016/j.nima.2019.03.092
dc.identifier.issn0168-9002
dc.identifier.obd43926305
dc.identifier.uri2-s2.0-85063760451
dc.identifier.urihttp://hdl.handle.net/11025/39604
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesNuclear Instruments and Methods in Physics Research, Aen
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© Elsevieren
dc.rights.accessrestrictedAccessen
dc.subject.translatedtransition radiationen
dc.subject.translatedTimepix3en
dc.subject.translatedGallium arsenideen
dc.subject.translatedsiliconen
dc.titleTransition radiation measurements with a Si and a GaAs pixel sensor on a Timepix3 chipen
dc.typečlánekcs
dc.typearticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen

Files