Assessment of three multiple cuff blood pressure devices
dc.contributor.author | Jílek, Jiří | |
dc.contributor.author | Štork, Milan | |
dc.date.accessioned | 2020-03-30T10:00:24Z | |
dc.date.available | 2020-03-30T10:00:24Z | |
dc.date.issued | 2019 | |
dc.description.abstract | Shortcomings of single cuff blood pressure devices have led to research of devices with more than one cuff for improved accuracy. We assessed two devices that use two cuffs and one device that uses three cuffs. The devices with two cuffs use one occluding arm cuff and one cuff that detects pulses that pass past the occluding cuff. The device with three cuffs uses pulse delay time. The advantages and the shortcomings of the devices are discussed in this paper. | en |
dc.format | 4 s. | cs |
dc.format.mimetype | application/pdf | |
dc.identifier.citation | JÍLEK, J., ŠTORK, M. Assessment of three multiple cuff blood pressure devices. In International Conference on Applied Electronics (AE 2019) : /proceedings/. Pilsen: University of West Bohemia, 2019. s. 79-82. ISBN 978-80-261-0813-9 , ISSN 1803-7232. | en |
dc.identifier.doi | 10.23919/AE.2019.8867036 | |
dc.identifier.isbn | 978-80-261-0813-9 | |
dc.identifier.issn | 1803-7232 | |
dc.identifier.obd | 43926952 | |
dc.identifier.uri | 2-s2.0-85074154626 | |
dc.identifier.uri | http://hdl.handle.net/11025/36787 | |
dc.language.iso | en | en |
dc.project.ID | LO1607/RICE-NETESIS - nové technologie a koncepce pro inteligentní průmyslové systémy (NETESIS) | cs |
dc.project.ID | SGS-2018-001/Výzkum a vývoj elektronických a komunikačních systémů ve vědeckých a inženýrských aplikacích | cs |
dc.publisher | University of West Bohemia | en |
dc.relation.ispartofseries | International Conference on Applied Electronics (AE 2019) : /proceedings/ | en |
dc.rights | © University of West Bohemia in Pilsen | en |
dc.rights.access | openAccess | en |
dc.subject.translated | blood pressure | en |
dc.subject.translated | cuff pulse | en |
dc.subject.translated | dual cuff | en |
dc.subject.translated | triple cuff | en |
dc.subject.translated | pulse detection | en |
dc.subject.translated | delay time | en |
dc.subject.translated | device validations | en |
dc.title | Assessment of three multiple cuff blood pressure devices | en |
dc.type | konferenční příspěvek | cs |
dc.type | postprint | cs |
dc.type | conferenceObject | en |
dc.type | postprint | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
dc.type.version | acceptedVersion | en |