| dc.description.abstract-translated | The descriptions and simulations of different differential order synchronous machine models are analyzed in this paper. Focus is paid on the Power System Analyses Toolbox models in the Simulink environment (MATLAB). The response of the models on the three-phase short circuit fault is evaluated, including pros and cons of each model as well as appropriate applications. The verification of the results is based on comparison with another independent synchronous machine model and analytical three phase short circuit calculation based on the operational measurements and observations. | en |
| dc.format | 7 s. | cs |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | VINŠ, M. NOHÁČ, K. SIROVÝ, M. Accuracy evaluation of synchronous generator models in PSAT. In 2021 IEEE 19th International Power Electronics and Motion Control Conference (PEMC) : /proceedings/. Piscaway: IEEE, 2021. s. 383-389. ISBN: 978-1-72815-660-6 | cs |
| dc.identifier.document-number | 723843000054 | |
| dc.identifier.doi | 10.1109/PEMC48073.2021.9432636 | |
| dc.identifier.isbn | 978-1-72815-660-6 | |
| dc.identifier.obd | 43932990 | |
| dc.identifier.uri | 2-s2.0-85107460236 | |
| dc.identifier.uri | http://hdl.handle.net/11025/46655 | |
| dc.language.iso | en | en |
| dc.project.ID | TN01000007/Národní centrum pro energetiku | cs |
| dc.publisher | IEEE | en |
| dc.relation.ispartofseries | 2021 IEEE 19th International Power Electronics and Motion Control Conference (PEMC) : /proceedings/ | en |
| dc.rights | Plný text je přístupný v rámci univerzity přihlášeným uživatelům. | cs |
| dc.rights | © IEEE | en |
| dc.rights.access | restrictedAccess | en |
| dc.subject.translated | accuracy | en |
| dc.subject.translated | different differential order models | en |
| dc.subject.translated | PSAT | en |
| dc.subject.translated | simulations | en |
| dc.subject.translated | simulink | en |
| dc.subject.translated | synchronous generator | en |
| dc.subject.translated | three phase short circuit | en |
| dc.subject.translated | evaluation | en |
| dc.title | Accuracy evaluation of synchronous generator models in PSAT | en |
| dc.type | konferenční příspěvek | cs |
| dc.type | ConferenceObject | en |
| dc.type.status | Peer-reviewed | en |
| dc.type.version | publishedVersion | en |