Energy Consumption Comparison of a Single Variable-Speed Pump and a System of Two Pumps: Variable-Speed and Fixed-Speed

dc.contributor.authorOshurbekov, Safarbek
dc.contributor.authorKazakbaev, Vadim
dc.contributor.authorPrakht, Vladimir
dc.contributor.authorDmitrievskii, Vladimir
dc.contributor.authorGevorkov, Levon
dc.date.accessioned2023-12-04T11:00:24Z
dc.date.available2023-12-04T11:00:24Z
dc.date.issued2020
dc.description.abstract-translatedThe energy efficiency of a multi-pump system consisting of two low-power (0.75 kW) pumps operating in parallel mode and a single-pump mechanism (1.5 kW) is compared in this study. For this purpose, mathematical models, experimental data, and data retrieved from the manuals provided by the pump manufacturers are used. The single-pump system is fed by a single variable speed drive. A multi-pump system running in parallel mode consists of two pumps. One of them is driven by an induction motor connected directly to the electrical grid and equipped with a throttle. Another pump is actuated by an induction motor fed by a variable speed drive. The flowrate of the liquid in the multi-pump is controlled with the help of speed variation and throttling. In the case of the single-pump system the conventional speed control method is applied during the analysis. For both pump system topologies, the daily and annual energy consumption is obtained. As a result of conducted calculations, it was shown that the multi-pump provides 29.8% savings in comparison to the single-pump system in the case of a typical flowrate profile.en
dc.format
dc.format14 s.cs
dc.format.mimetypeapplication/pdf
dc.identifier.citationOSHURBEKOV, S. KAZAKBAEV, V. PRAKHT, V. DMITRIEVSKII, V. GEVORKOV, L. Energy Consumption Comparison of a Single Variable-Speed Pump and a System of Two Pumps: Variable-Speed and Fixed-Speed. Applied Sciences, 2020, roč. 10, č. 24, s. 1-14. ISSN: 2076-3417cs
dc.identifier.document-number602955200001
dc.identifier.doi10.3390/app10248820
dc.identifier.issn2076-3417
dc.identifier.obd43940724
dc.identifier.uri2-s2.0-85103860760
dc.identifier.urihttp://hdl.handle.net/11025/54920
dc.language.iso
dc.language.isoenen
dc.publisherMDPIen
dc.relation.ispartofseriesApplied Sciencesen
dc.rights© The Author(s)en
dc.rights.accessopenAccessen
dc.subject.translatedcentrifugal pumpen
dc.subject.translatedenergy eciencyen
dc.subject.translatedinduction motoren
dc.subject.translatedthrottling controlen
dc.subject.translatedvariable speed controlen
dc.titleEnergy Consumption Comparison of a Single Variable-Speed Pump and a System of Two Pumps: Variable-Speed and Fixed-Speeden
dc.typečlánekcs
dc.typearticleen
dc.type.status
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen

Files

Original bundle
Showing 1 - 1 out of 1 results
No Thumbnail Available
Name:
applsci-10-08820.pdf
Size:
2.55 MB
Format:
Adobe Portable Document Format