The influence of the dead time duration and switching frequency on the input current distortion of voltage-source active rectifiers
| dc.contributor.author | Kůs, Václav | |
| dc.contributor.author | Josefová, Tereza | |
| dc.date.accessioned | 2019-09-24T09:31:47Z | |
| dc.date.available | 2019-09-24T09:31:47Z | |
| dc.date.issued | 2015 | |
| dc.description.abstract-translated | This paper is focused on the influence combinations of the dead time duration and switching frequency on the drawn current from the grid by voltage-source active rectifiers. Newly the various definitions of the total harmonic distortion of the current are used. According to the EU standard the total harmonic distortion of the current is calculated up to the 50th harmonic | en |
| dc.format | 4 s. | cs |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | 2015 International Conference on Applied Electronics: Pilsen, 8th – 9th September 2015, Czech Republic, p.131-134. | en |
| dc.identifier.isbn | 978-80-261-0385-1 (Print) | |
| dc.identifier.isbn | 978-80-261-0386-8 (Online) | |
| dc.identifier.issn | 1803-7232 (Print) | |
| dc.identifier.issn | 1805-9597 (Online) | |
| dc.identifier.uri | http://hdl.handle.net/11025/35107 | |
| dc.language.iso | en | en |
| dc.publisher | Západočeská univerzita v Plzni | cs |
| dc.rights | © University of West Bohemia | en |
| dc.rights.access | openAccess | en |
| dc.subject | harmonická analýza | cs |
| dc.subject | spínací frekvence | cs |
| dc.subject | usměrňovače | cs |
| dc.subject | celkové harmonické zkreslení | cs |
| dc.subject | standardy | cs |
| dc.subject | modulace šířky pulsu | cs |
| dc.subject | výkonové harmonické filtry | cs |
| dc.subject.translated | harmonic analysis | en |
| dc.subject.translated | switching frequency | en |
| dc.subject.translated | rectifiers | en |
| dc.subject.translated | total harmonic distortion | en |
| dc.subject.translated | standards | en |
| dc.subject.translated | pulse width modulation | en |
| dc.subject.translated | power harmonic filters | en |
| dc.title | The influence of the dead time duration and switching frequency on the input current distortion of voltage-source active rectifiers | en |
| dc.type | konferenční příspěvek | cs |
| dc.type | conferenceObject | en |
| dc.type.status | Peer-reviewed | en |
| dc.type.version | publishedVersion | en |
Files
Original bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- Kus.pdf
- Size:
- 338.24 KB
- Format:
- Adobe Portable Document Format
- Description:
- Plný text
License bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: