Modelling of the mechanical behaviour of porcine carotid artery undergoing inflation-deflation test
Files
Date issued
2010
Journal Title
Journal ISSN
Volume Title
Publisher
University of West Bohemia
Abstract
Samples of porcine carotid artery are examined using Tissue bath MAYFLOWER, Perfusion of tubular organs
Version, Type 813/6. Pressure-diameter diagrams are obtained for fixed axial extension and volumetric flow rate.
Finite element analysis of the experiment, performed using COMSOL software, indicates a negligible effect of
given flow rate on the mechanical response of the tested sample. Also the effect of clamped ends is shown to
be local only. Hence, static analysis in MATLAB software is performed considering the arterial segment as an
incompressible hyperelastic axisymmetric tube. Residual stress at the load-free configuration is taken into account
resulting in the overall stiffening of the model. Comparison of theoretical and experimental pressure-diameter
curves results in the identification of material parameters using the least square method. In addition to classical hyperelastic
models, such as the neo-Hookean and the Fung’s exponential, two-scale model mimicking arrangement
of soft tissue is considered.
Description
Subject(s)
aplikovaná mechanika, hyperelasticita, měkké tkáně
Citation
Applied and Computational Mechanics. 2010, vol. 4, no. 2, p. 251-262.