Simulation of temperature evolution during departure from nucleate boiling induced by electric arc heating
| dc.contributor.author | Vnenk, Petr | |
| dc.contributor.editor | Mašata, David | |
| dc.date.accessioned | 2025-09-22T08:23:43Z | |
| dc.date.available | 2025-09-22T08:23:43Z | |
| dc.date.issued | 2025 | |
| dc.description.abstract-translated | This part of the study presents a method for simulating departure from nucleate boiling (DNB) using an electric arc heating device, with temperature measured by thermocouple sensors. The system enables fast and repeatable local heating, reaching temperatures of up to 400 °C. Both AC and DC arc modes were tested, with AC showing better stability. Temperature data were collected and processed using the MeThOp software. The method proved suitable for evaluating thermal sensor response, and comparison with reference data confirmed that the arc-based approach is eSective for simplified DNB simulation. | en |
| dc.format | 2 s. | cs |
| dc.identifier.isbn | 978-80-261-1307-2 | |
| dc.identifier.isbn | 978-80-261-1308-9 (printed) | |
| dc.identifier.uri | http://hdl.handle.net/11025/62821 | |
| dc.language.iso | en | en |
| dc.publisher | University of West Bohemia in Pilsen | en |
| dc.rights | © University of West Bohemia in Pilsen | en |
| dc.rights.access | openAccess | en |
| dc.subject | poster | cs |
| dc.subject.translated | poster | en |
| dc.title | Simulation of temperature evolution during departure from nucleate boiling induced by electric arc heating | en |
| dc.type | konferenční příspěvek | cs |
| dc.type | conferenceObject | en |
| dc.type.status | Peer reviewed | en |
| local.files.count | 2 | * |
| local.files.size | 783620 | * |
| local.has.files | yes | * |
Files
Original bundle
License bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: