Occlusion evaluation in hierarchical radiosity

dc.contributor.authorDupuy, Yann
dc.contributor.authorPaulin, Mathias
dc.contributor.authorCaubet, René
dc.contributor.editorSkala, Václav
dc.date.accessioned2015-09-18T13:15:16Z
dc.date.available2015-09-18T13:15:16Z
dc.date.issued2001
dc.description.abstract-translatedIn any hierarchical radiosity method, the most expensive part is the evaluation of the visibility. Many methods use sampling and ray casting to determine this term. Space partitioning considerably speeds up the computation process. Partitioning with shafts, leads to a quite precise subdivision of 3D space, as far as interactions between pair of objects are concerned. The use of bounding boxes allows to speed-up many computations, such as collision or intersection detection. Those intersections can profitably be used to determine visibility between objects. Axis aligned bounding boxes allow very fast evaluation of intersection, but are not that precise, whereas oriented bounding boxes, much closer to the 3D object achieve more accurate visibility evaluation. We present here a method that allow to quickly and accurately determine the relative position of an object and a shaft (inside, outside, occluding), and how to implement it in a hierarchical radiosity algorithm, in order to limit the hierarchy construction where not necessary.en
dc.format8 s.cs
dc.format.mimetypeapplication/pdf
dc.identifier.citationJournal of WSCG. 2001, vol. 9, no. 1-3.en
dc.identifier.issn1213-6972 (print)
dc.identifier.issn1213-6980 (CD-ROM)
dc.identifier.issn1213-6964 (online)
dc.identifier.urihttp://hdl.handle.net/11025/15767
dc.identifier.urihttp://wscg.zcu.cz/wscg2001/WSCG2001_Program.htm
dc.language.isoenen
dc.publisherVáclav Skala - UNION Agencycs
dc.relation.ispartofseriesJournal of WSCGen
dc.rights© Václav Skala - UNION Agencycs
dc.rights.accessopenAccessen
dc.subjectradiozitacs
dc.subjectosacs
dc.subjectviditelnostcs
dc.subjectabsorbovánícs
dc.subject.translatedradiosityen
dc.subject.translatedshaften
dc.subject.translatedvisibilityen
dc.subject.translatedocclusionen
dc.titleOcclusion evaluation in hierarchical radiosityen
dc.typečlánekcs
dc.typearticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen

Files

Original bundle
Showing 1 - 1 out of 1 results
No Thumbnail Available
Name:
R225.pdf
Size:
525.66 KB
Format:
Adobe Portable Document Format
Description:
Plný text
License bundle
Showing 1 - 1 out of 1 results
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: