| dc.description.abstract | This work focuses on high-temperature insulation materials for cables intended for use in nuclear power plants, emphasizing their stability and durability under harsh operating conditions. The introduction provides an overview of cable structures and insulation materials used in cable technology and describes diagnostic methods for analyzing their structural and phenomenological properties. In the experimental part, PEEK (polyetheretherketone) and XLPE (cross-linked polyethylene) insulated cables were selected for testing. The cables were subjected to accelerated thermal aging to simulate 60 years of operation in a nuclear power plant environment, with PEEK additionally undergoing radiation aging. The results show that XLPE exhibited significant degradation during thermal aging, while PEEK maintained stable structural and electrical properties throughout the tests. | en |
| dc.format | 4 | |
| dc.identifier.doi | 10.1109/CEIDP61707.2025.11218423 | |
| dc.identifier.isbn | 979-8-3315-8902-8 | |
| dc.identifier.issn | 0084-9162 | |
| dc.identifier.obd | 43947704 | |
| dc.identifier.orcid | Kupilík, Tomáš 0009-0004-2860-3927 | |
| dc.identifier.orcid | Prosr, Pavel 0000-0002-7484-2492 | |
| dc.identifier.orcid | Pihera, Josef 0000-0002-0521-6869 | |
| dc.identifier.uri | http://hdl.handle.net/11025/67376 | |
| dc.language.iso | en | |
| dc.project.ID | SGS-2024-008 | |
| dc.publisher | IEEE | |
| dc.relation.ispartofseries | 100th IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2025 | |
| dc.subject | XLPE | en |
| dc.subject | PEEK | en |
| dc.subject | cable | en |
| dc.subject | radiation aging | en |
| dc.subject | thermal aging | en |
| dc.title | Relative Resistance of PEEK and XLPE Insulated LV Cables in Nuclear Power Plants | en |
| dc.type | Stať ve sborníku (D) | |
| dc.type | STAŤ VE SBORNÍKU | |
| dc.type.status | Published Version | |
| local.files.count | 1 | * |
| local.files.size | 527670 | * |
| local.has.files | yes | * |
| local.identifier.eid | 2-s2.0-105025011325 |
Files
Original bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- Relative_Resistance_of_PEEK_and_XLPE_Insulated_LV_Cables_in_Nuclear_Power_Plants.pdf
- Size:
- 515.3 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: