Possibilities and limits of human temperature measurement by thermographic methods
| dc.contributor.author | Švantner, Michal | |
| dc.contributor.author | Lang, Vladislav | |
| dc.contributor.author | Skála, Jiří | |
| dc.contributor.author | Kohlschütter, Tomáš | |
| dc.contributor.author | Honner, Milan | |
| dc.contributor.author | Muzika, Lukáš | |
| dc.contributor.author | Kosová, Eliška | |
| dc.date.accessioned | 2025-06-27T10:11:34Z | |
| dc.date.available | 2025-06-27T10:11:34Z | |
| dc.date.issued | 2022 | |
| dc.date.updated | 2025-06-27T10:11:34Z | |
| dc.description.abstract | Increased temperature of humans is one of the symptoms of many infectious diseases and it is thus an important diagnostic tool. A contact based temperature measurement is a proven standard. However, infrared methods have also been developed and applied over a long period due to their advantages of a non-contact and fast measurement. This study deals with possibilities and limitations of infrared/thermographic human temperature measurement. A short review of a use of infrared temperature measurement in medical applications is provided. Experiments and statistical based evaluation to confirm possibilities, expected accuracy and limits of thermography based human temperature measurement are introduced. Results presented in this study show, that a standard deviation of the thermographic measurement was 0.4-0.9 °C and differences from the armpit measurement were up to 0.6 °C, based on the used IR camera, even though a near ideal measurement conditions and a permanent black body correction was used. | en |
| dc.format | 5 | |
| dc.identifier.document-number | 000853070300006 | |
| dc.identifier.doi | 10.1109/MetroLivEnv54405.2022.9826942 | |
| dc.identifier.isbn | 978-1-66540-893-6 | |
| dc.identifier.obd | 43943567 | |
| dc.identifier.orcid | Švantner, Michal 0000-0001-9391-7069 | |
| dc.identifier.orcid | Lang, Vladislav 0000-0003-0775-2822 | |
| dc.identifier.orcid | Skála, Jiří 0000-0002-1245-825X | |
| dc.identifier.orcid | Kohlschütter, Tomáš 0000-0001-6233-7133 | |
| dc.identifier.orcid | Honner, Milan 0000-0003-1064-0936 | |
| dc.identifier.orcid | Muzika, Lukáš 0000-0003-4898-7169 | |
| dc.identifier.uri | http://hdl.handle.net/11025/62011 | |
| dc.language.iso | en | |
| dc.project.ID | EF18_069/0010018 | |
| dc.publisher | IEEE | |
| dc.relation.ispartofseries | 2022 IEEE International Workshop on Metrology for Living Environment, MetroLivEn 2022 | |
| dc.subject | thermography | en |
| dc.subject | human temperature measurement | en |
| dc.subject | thermographic measurement | en |
| dc.title | Possibilities and limits of human temperature measurement by thermographic methods | en |
| dc.type | Stať ve sborníku (D) | |
| dc.type | STAŤ VE SBORNÍKU | |
| dc.type.status | Published Version | |
| local.files.count | 1 | * |
| local.files.size | 1092953 | * |
| local.has.files | yes | * |
| local.identifier.eid | 2-s2.0-85135838779 |
Files
Original bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- Possibilities_and_limits_of_human_temperature_measurement_by_thermographic_methods.pdf
- Size:
- 1.04 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: