Partial discharge diagnostic of medium voltage switch-gears under operating conditions using a special PD-probe
dc.contributor.author | Haller, Rainer | |
dc.contributor.editor | Pihera, Josef | |
dc.contributor.editor | Steiner, František | |
dc.date.accessioned | 2012-08-02T08:04:46Z | |
dc.date.available | 2012-08-02T08:04:46Z | |
dc.date.issued | 2007 | |
dc.description.abstract-translated | As an essential tool for condition based maintenance of electrical equipment, PD measurements under real operating conditions are becoming ever more important. The main problems associated with these diagnostic on-site measurements are the measuring sensitivity and reproducibility of measured values with respect to calibration conditions. This paper discusses the problems of on-site PD measurement in medium voltage switchgear using a special PD-probe. It will be shown, that the maximum PD-sensitivity can be reached by using a capacitive sensor in conjunction with the PD-probe and by connecting of elements with resonance characteristics. For measurements made under operating conditions on real switchgear, a measurement sensitivity of < 20 pC could be reached. | en |
dc.format | 4 s. | cs |
dc.format.mimetype | application/pdf | |
dc.identifier.citation | Electroscope. 2007, č. 2. | cs |
dc.identifier.issn | 1831-4564 | |
dc.identifier.uri | http://147.228.94.30/images/PDF/Rocnik2007/spec_cislo_diagnostika07/r0c2c5.pdf | |
dc.identifier.uri | http://hdl.handle.net/11025/420 | |
dc.language.iso | en | en |
dc.publisher | Západočeská univerzita v Plzni, Fakulta elektrotechnická | cs |
dc.relation.ispartofseries | Electroscope | cs |
dc.rights | Copyright © 2007-2010 Electroscope. All Rights Reserved. | en |
dc.rights.access | openAccess | en |
dc.subject | částečné náboje | cs |
dc.subject | elektrotechnická diagnostika | cs |
dc.subject | vypínače | cs |
dc.subject | měření pupilární distance | cs |
dc.subject.translated | partial discharges | en |
dc.subject.translated | electrical diagnostics | en |
dc.subject.translated | switches | en |
dc.subject.translated | pupillary distance measurement | en |
dc.title | Partial discharge diagnostic of medium voltage switch-gears under operating conditions using a special PD-probe | en |
dc.type | článek | cs |
dc.type | konferenční příspěvek | cs |
dc.type | article | en |
dc.type | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |