| dc.description.abstract | In this study the impact of electromagnetic field generated by mobile phone (f=900 MHz), electromagnetic field with industrial frequency generated by high voltage alternating current transmission lines (f=50 Hz, E=10 kV/m), and also simultaneous action of those fields on the intensity of bone turnover process in male rats was estimated by means of analysis of serum concentration of calcium, phosphorus, as well as specific markers of bone formation and bone resorption. It was concluded that 4-week lasting exposure to both forms of electromagnetic field causes the intensification of bone turnover, resulting in the increase of serum concentrations of osteocalcin, pyridinoline and crosslinked alpha-2 N-terminal telopeptide of collagen type I. The obtained effect was dependent on frequency and power density of used electromagnetic fields. | en |
| dc.format | 2 s. | cs |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | ISTET 2013: International Symposiumon Theoretical Electrical Engineering: 24th – 26th June 2013: Pilsen, Czech Republic, p. IV-33-IV-34. | en |
| dc.identifier.isbn | 978-80-261-0246-5 | |
| dc.identifier.uri | http://hdl.handle.net/11025/11516 | |
| dc.language.iso | en | en |
| dc.publisher | University of West Bohemia | en |
| dc.relation.ispartofseries | ISTET: International Symposium on Theoretical Electrical Engineering | en |
| dc.rights | © University of West Bohemia | en |
| dc.rights.access | openAccess | en |
| dc.subject | elektromagnetické pole | cs |
| dc.subject | mobilní telefon | cs |
| dc.subject | kostní obrat | cs |
| dc.subject.translated | electromagnetic field | en |
| dc.subject.translated | mobile | en |
| dc.subject.translated | bone turnover | en |
| dc.title | Impact of Selected Electromagnetic Fields on Bone Turnover Markers in Rats | en |
| dc.type | konferenční příspěvek | cs |
| dc.type | conferenceObject | en |
| dc.type.status | Peer-reviewed | en |
| dc.type.version | publishedVersion | en |
Files
Original bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- Teister.pdf
- Size:
- 69.34 KB
- Format:
- Adobe Portable Document Format
- Description:
- Plný text
License bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: