Abstract
The article deals with the stress-strain analysis of human mandible in the physiological state and after the dental
implant application. The evaluation is focused on assessing of the cancellous bone tissue modeling-level.
Three cancellous bone model-types are assessed: Non-trabecular model with homogenous isotropic material, nontrabecular
model with inhomogeneous material obtained from computer tomography data using CT Data Analysis
software, and trabecular model built from mandible section image. Computational modeling was chosen as the
most suitable solution method and the solution on two-dimensional level was carried out. The results show that
strain is more preferable value than stress in case of evaluation of mechanical response in cancellous bone. The
non-trabecular model with CT-obtained material model is not acceptable for stress-strain analysis of the cancellous
bone for singularities occurring on interfaces of regions with different values of modulus of elasticity.