Influence of fluidelastic vibration frequency on predicting damping controlled instability using a quasi-steady model in a normal triangular tube array

dc.contributor.authorEret, Petr
dc.date.accessioned2025-06-20T08:56:58Z
dc.date.available2025-06-20T08:56:58Z
dc.date.issued2024
dc.date.updated2025-06-20T08:56:58Z
dc.description.abstractResearchers have applied theoretical and CFD models for years to analyze the fluidelastic instability (FEI) of tube arrays in steam generators and other heat exchangers. The accuracy of each approach has typically been evaluated using the discrepancy between the experimental critical flow velocity and the predicted value. In the best cases, the predicted critical flow velocity was within an order of magnitude comparable to the measured one. This paper revisits the quasi-steady approach for damping controlled FEI in a normal triangular array with a pitch ratio of P/d=1.375. The method addresses the fluidelastic frequency at the stability threshold as an input parameter for the approach. The excellent agreement between the estimated stability thresholds and the equivalent experimental results suggests that the fluidelastic frequency must be included in the quasi-steady analysis, which requires minimal computing time and experimental data. In addition, the model allows a simple time delay analysis regarding flow convective and viscous effects.en
dc.format6
dc.identifier.document-number001226592100001
dc.identifier.doi10.1016/j.net.2023.11.049
dc.identifier.issn1738-5733
dc.identifier.obd43942017
dc.identifier.orcidEret, Petr 0000-0002-6084-7516
dc.identifier.urihttp://hdl.handle.net/11025/61644
dc.language.isoen
dc.relation.ispartofseriesNuclear Engineering and Technology
dc.rights.accessA
dc.subjectfluidelastic frequencyen
dc.subjectfluidelastic instabilityen
dc.subjectheat exchanger tube arrayen
dc.subjectquasi-steady modelen
dc.subjectsingle degree of freedom tubeen
dc.subjecttime delayen
dc.titleInfluence of fluidelastic vibration frequency on predicting damping controlled instability using a quasi-steady model in a normal triangular tube arrayen
dc.typeČlánek v databázi WoS (Jimp)
dc.typeČLÁNEK
dc.type.statusPublished Version
local.files.count1*
local.files.size630424*
local.has.filesyes*
local.identifier.eid2-s2.0-85179037749

Files

Original bundle
Showing 1 - 1 out of 1 results
No Thumbnail Available
Name:
1-s2.0-S1738573323005491-main.pdf
Size:
615.65 KB
Format:
Adobe Portable Document Format
License bundle
Showing 1 - 1 out of 1 results
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections