| dc.description.abstract-translated | Shortcomings of single cuff blood pressure devices have led to research of devices with more than one cuff for improved accuracy. We assessed two devices that use two cuffs and one device that uses three cuffs. The devices with two cuffs use one occluding arm cuff and one cuff that detects pulses that pass past the occluding cuff. The device with three cuffs uses pulse delay time. The advantages and the shortcomings of the devices are discussed in this paper. | en |
| dc.format | 4 s. | cs |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | 2019 International Conference on Applied Electronics: Pilsen, 10th – 11th September 2019, Czech Republic, p.79-82. | en |
| dc.identifier.isbn | 978–80–261–0812–2 (Online) | |
| dc.identifier.isbn | 978–80–261–0813–9 (Print) | |
| dc.identifier.issn | 1803–7232 (Print) | |
| dc.identifier.issn | 1805-9597 (Online) | |
| dc.identifier.uri | http://hdl.handle.net/11025/35520 | |
| dc.language.iso | en | en |
| dc.publisher | Západočeská univerzita v Plzni | cs |
| dc.rights | © Západočeská univerzita v Plzni | cs |
| dc.rights.access | openAccess | en |
| dc.subject | krevní tlak | cs |
| dc.subject | manžetový puls | cs |
| dc.subject | duální manžeta | cs |
| dc.subject | trojitá manžeta | cs |
| dc.subject | detekce pulsu | cs |
| dc.subject | zpoždění | cs |
| dc.subject | validace zařízení | cs |
| dc.subject.translated | blood pressure | en |
| dc.subject.translated | cuff pulse | en |
| dc.subject.translated | dual cuff | en |
| dc.subject.translated | triple cuff | en |
| dc.subject.translated | pulse detection | en |
| dc.subject.translated | delay time | en |
| dc.subject.translated | device validations | en |
| dc.title | Assessment of Three Multiple Cuff Blood Pressure Devices | en |
| dc.type | konferenční příspěvek | cs |
| dc.type | conferenceObject | en |
| dc.type.status | Peer-reviewed | en |
| dc.type.version | publishedVersion | en |
Files
Original bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- Jilek.pdf
- Size:
- 169.26 KB
- Format:
- Adobe Portable Document Format
- Description:
- Plný text
License bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: