Advanced Control of Full Electric and Hybrid Vehicles

dc.contributor.authorNjawah achiri, Humphrey Mokom
dc.contributor.refereeValouch Viktor, Prof. Ing. CSc.
dc.contributor.refereeVorel Pavel, Doc. Ing. Ph.D.
dc.contributor.refereeDamec Vladislav, Ing. Ph.D.
dc.date.accepted2022-9-30
dc.date.accessioned2022-11-10T14:48:12Z
dc.date.available2013-11-1
dc.date.available2022-11-10T14:48:12Z
dc.date.issued2022
dc.date.submitted2022-9-1
dc.description.abstractA thermal model to accurately estimate the junction temperature of inverters is developed. State of the art methods for determining thermal impedance networks for IGBT modules are used in the establishment of the relationship between the measured transistor or diode voltage and temperature under homogenous temperature distribution across the IGBT module. The junction temperature is recomputed from the established voltage-temperature relationship and used in determining the thermal impedance network. These methods requires accurate measurement of voltage drop across the transistors and diodes under specific designed heating and cooling profiles. Validation of the junction temperature is done using infrared camera or sensors placed closed to the transistors or diodes (in some cases and open IGBT module) so that the measured temperature is as close to the junction as possible. In this thesis we propose an alternative method for determining the IGBT thermal impedance network using the principles of least squares. This method uses measured temperatures for defined heating and cooling cycles under different cooling conditions to determine the thermal impedance network. The results from the proposed method are compared with those obtained using state of the art methods. Based on the calculated junction temperature, an optimal thermal management strategy of the electric drivetrain based on adaptive linear current derating and I2t derating to allow for maximum possible torque and optimum thermal protection of the electric drivetrain is implemented.cs
dc.description.abstract-translatedA thermal model to accurately estimate the junction temperature of inverters is developed. State of the art methods for determining thermal impedance networks for IGBT modules are used in the establishment of the relationship between the measured transistor or diode voltage and temperature under homogenous temperature distribution across the IGBT module. The junction temperature is recomputed from the established voltage-temperature relationship and used in determining the thermal impedance network. These methods requires accurate measurement of voltage drop across the transistors and diodes under specific designed heating and cooling profiles. Validation of the junction temperature is done using infrared camera or sensors placed closed to the transistors or diodes (in some cases and open IGBT module) so that the measured temperature is as close to the junction as possible. In this thesis we propose an alternative method for determining the IGBT thermal impedance network using the principles of least squares. This method uses measured temperatures for defined heating and cooling cycles under different cooling conditions to determine the thermal impedance network. The results from the proposed method are compared with those obtained using state of the art methods. Based on the calculated junction temperature, an optimal thermal management strategy of the electric drivetrain based on adaptive linear current derating and I2t derating to allow for maximum possible torque and optimum thermal protection of the electric drivetrain is implemented.en
dc.description.resultObhájeno
dc.format70
dc.identifier92013
dc.identifier.urihttp://hdl.handle.net/11025/50294
dc.language.isoen
dc.publisherZápadočeská univerzita v Plzni
dc.relation.isreferencedbyhttps://portal.zcu.cz/StagPortletsJSR168/CleanUrl?urlid=prohlizeni-prace-detail&praceIdno=92013
dc.rightsPlný text práce je přístupný bez omezení
dc.subjectigbt junction temperaturecs
dc.subjectanalytical thermal modelcs
dc.subjectleast squares methodcs
dc.subject.translatedigbt junction temperatureen
dc.subject.translatedanalytical thermal modelen
dc.subject.translatedleast squares methoden
dc.thesis.degree-grantorZápadočeská univerzita v Plzni. Fakulta elektrotechnická
dc.thesis.degree-levelDoktorský
dc.thesis.degree-namePh.D.
dc.thesis.degree-programElectrical Engineering and Information Technology 
dc.titleAdvanced Control of Full Electric and Hybrid Vehiclescs
dc.typedisertační práce

Files

Original bundle
Showing 1 - 5 out of 5 results
No Thumbnail Available
Name:
Analytical Models for IGBT Junction Temperature Estimation.pdf
Size:
3.12 MB
Format:
Adobe Portable Document Format
Description:
Plný text práce
No Thumbnail Available
Name:
achiri_opon.pdf
Size:
2.79 MB
Format:
Adobe Portable Document Format
Description:
Posudek oponenta práce
No Thumbnail Available
Name:
achiri_publ.pdf
Size:
200.33 KB
Format:
Adobe Portable Document Format
Description:
Posudek vedoucího práce
No Thumbnail Available
Name:
achiri_zapis.pdf
Size:
668.31 KB
Format:
Adobe Portable Document Format
Description:
Průběh obhajoby práce
No Thumbnail Available
Name:
Publications_Achiri.pdf
Size:
200.67 KB
Format:
Adobe Portable Document Format
Description:
VŠKP - příloha