Vector-valued image restoration with applications to magnetic resonance velocity imaging

dc.contributor.authorNg, Yin-Heung Pauline
dc.contributor.authorYang, Guang-Zhong
dc.contributor.editorSkala, Václav
dc.date.accessioned2013-04-16T09:47:27Z
dc.date.available2013-04-16T09:47:27Z
dc.date.issued2003
dc.description.abstractThe analysis of blood flow patterns and the interaction between salient topological flow features and cardiovascular structure plays an important role in the study of cardiovascular function. Flow velocity images acquired by Magnetic Resonance (MR) velocity imaging are generally subject to noise that are intrinsic to system hardware setup and those specific to patient movement in relation to imaging sequence designs. To improve the accuracy of the quantitative analysis of the evolution of topological flow features, it is essential to restore the original flow fields so that the associated critical points can be more reliably detected. In this study, we propose a total variation based variational method for the restoration of flow vector fields. The method is formulated as a constrained optimisation problem by minimizing the total variation energy of the normalized velocity field subject to a constraint that depends on the noise level. The effectiveness of this restoration method greatly depends on the choice of the regularization parameter in the formulation of the optimisation problem. A new computational algorithm based on the First Order Lagrangian method is proposed, which determines the optimal value of the regularization parameter while solving the minimisation problem. The proposed method has been validated with both simulated flow data and MR velocity maps acquired from patients with sequential MR examination following myocardial infarction.en
dc.format8 s.cs
dc.format.mimetypeapplication/pdf
dc.identifier.citationJournal of WSCG. 2003, vol. 11, no. 1-3.en
dc.identifier.issn1213-6972
dc.identifier.urihttp://wscg.zcu.cz/wscg2003/Papers_2003/F47.pdf
dc.identifier.urihttp://hdl.handle.net/11025/1667
dc.language.isoenen
dc.publisherUNION Agency – Science Presscs
dc.relation.ispartofseriesJournal of WSCGen
dc.rights© UNION Agency – Science Presscs
dc.rights.accessopenAccessen
dc.subjectrekonstrukce obrazucs
dc.subjectmagnetická rezonancecs
dc.subjectzobrazování rychlostics
dc.subject.translatedimage restorationen
dc.subject.translatedmagnetic resonanceen
dc.subject.translatedvelocity imagingen
dc.titleVector-valued image restoration with applications to magnetic resonance velocity imagingen
dc.typečlánekcs
dc.typearticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen

Files

Original bundle
Showing 1 - 1 out of 1 results
No Thumbnail Available
Name:
F47.pdf
Size:
1.5 MB
Format:
Adobe Portable Document Format
License bundle
Showing 1 - 1 out of 1 results
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
OPEN License Selector