On the level of computational model of a human skull: a comparative study

Date issued

2018

Journal Title

Journal ISSN

Volume Title

Publisher

University of West Bohemia

Abstract

In this study, different patient-specific computational models of the skull, which are often used in literature, were investigated, analysed and compared.The purpose of this studywas to demonstrate the differences in computational model creation and results in case different computationalmodels based on same computed tomography (CT) dataset are used. The selection of computationalmodel directly influences the values of investigated parameters. The effort is to demonstrate, how the selection of the computational model influences the results of biomechanically relevant parameters. The comparison was based on total displacement of the skull and von Mises strain investigated around predefined paths around the skull. The strain values were evaluated according to criterion from literature. The results were obtained using finite element method. The values of the displacement of the skull were higher in case of considering cancellous bone tissue due to its poor material properties or heterogeneous material properties. The same situation occurred during the evaluation of strain. The values were higher in models which include cancellous bone tissue in the structure.

Description

Subject(s)

lebka, metoda konečných prvků, pevnost, skořápka, srovnání, modelování

Citation

Applied and Computational Mechanics. 2018, vol. 12, no. 1, p. 5-16.
OPEN License Selector