Open Phase Condition and its Impact on the Induction Machine

Abstract

The article describes the methodology for calculating the heating of an induction machine with an asymmetrical power supply. Parasitic torques and the effect on the machine torque curve are shown. The goal is to determine how long the motor can still be operated with a given voltage asymmetry before the allowable temperature is exceeded.

Description

Subject(s)

induction motor, open phase condition, warm-up of motor, symmetrical components