Impact of probe configuration on cracks’ resolution in pulsed eddy current non-destructive evaluation
dc.contributor.author | Michniakova, Mária | |
dc.contributor.author | Janoušek, Ladislav | |
dc.contributor.author | Smetana, Milan | |
dc.contributor.editor | Kropík, Petr | |
dc.date.accessioned | 2017-04-07T09:32:17Z | |
dc.date.available | 2017-04-07T09:32:17Z | |
dc.date.issued | 2011 | |
dc.description.abstract-translated | Pulsed eddy current non-destructive evaluation is concerned in the paper. Impact of eddy-current probe’s configuration on response signals, especially on crack’s depth resolution from the signals is numerically investigated. Orientation of an exciting coil of the probe regarding surface of a tested material is changed while the coil’s dimensions are varied at the same time to evaluate influence of the parameters on induction coupling between the probe and the material. The induction coupling affects information transfer between the probe and the material and consequently it influences the resolution of detected defects. Numerical simulations with various diameters of the coil are then performed and evaluated to investigate impact of this parameter on resolution of defects with different depths. | en |
dc.format | 2 s. | cs |
dc.format.mimetype | application/pdf | |
dc.identifier.citation | AMTEE ’11 : tenth international conference on Advanced Methods in the Theory of Electrical Engineering : September 06-09, 2011 [Cheb, Czech Republic], p. VIII-7-8. | en |
dc.identifier.isbn | 978-80-7043-993-7 | |
dc.identifier.uri | http://cpee.zcu.cz/AMTEE/ArchivedProceedings.aspx | |
dc.identifier.uri | http://hdl.handle.net/11025/25936 | |
dc.language.iso | en | en |
dc.publisher | University of West Bohemia | en |
dc.rights | © University of West Bohemia | en |
dc.rights.access | openAccess | en |
dc.subject | nedestruktivní hodnocení | cs |
dc.subject | pulzované vířivé proudy | cs |
dc.subject | signál odezvy | cs |
dc.subject | hloubka vady | cs |
dc.subject | rozlišení | cs |
dc.subject.translated | non-destructive evaluation | en |
dc.subject.translated | pulsed eddy currents | en |
dc.subject.translated | response signal | en |
dc.subject.translated | depth of defect | en |
dc.subject.translated | resolution | en |
dc.title | Impact of probe configuration on cracks’ resolution in pulsed eddy current non-destructive evaluation | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
Files
Original bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- Michniakova.pdf
- Size:
- 42.19 KB
- Format:
- Adobe Portable Document Format
- Description:
- Plný text
License bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: