Diagnostic Device for Photomultiplier Tubes at ARP ToF Detector
dc.contributor.author | Georgiev, Vjačeslav | |
dc.contributor.author | Vavroch, Ondřej | |
dc.contributor.author | Zich, Jan | |
dc.contributor.author | Nožka, Libor | |
dc.contributor.editor | Pinker, Jiří | |
dc.date.accessioned | 2020-11-05T09:23:13Z | |
dc.date.available | 2020-11-05T09:23:13Z | |
dc.date.issued | 2020 | |
dc.description.abstract-translated | Long-term usage of photomultiplier tubes (PMTs) led to the discovery of aging effects especially in harsh environment as a radiation is. Aging decreases the efficiency of the PMTs. This means PMTs need to the recalibration after some time. Because CERN′s Large Hadron Collider (LHC) runs for few years, the diagnostics of the PMTs is necessary. Eventual recalibration without removing the PMT is possible to accomplish by integrating the light source nearby PMT′s chassis. The light source should by as precise as possible. The used LED source needs a driver. The driver consists of controllable power source and timing controller. The perfect timing of the pulses is controlled by FPGA. An attention to the radiation hardened parts was needed because of the device proximity to the radiation source. The development and testing of the PMT diagnostic device (PDD) are described in this paper. | en |
dc.format | 4 s. | cs |
dc.format.mimetype | application/pdf | |
dc.identifier.citation | 2020 International Conference on Applied Electronics: Pilsen, 8th – 9h September 2020, Czech Republic. | en |
dc.identifier.isbn | 978-80-261-0891-7 (Print) | |
dc.identifier.isbn | 978-80-261-0892-4 (Online) | |
dc.identifier.issn | 1803-7232 (Print) | |
dc.identifier.issn | 1805-9597 (Online) | |
dc.identifier.uri | http://hdl.handle.net/11025/39904 | |
dc.language.iso | en | en |
dc.publisher | Západočeská univerzita v Plzni | cs |
dc.rights | © Západočeská univerzita v Plzni | cs |
dc.rights.access | openAccess | en |
dc.subject | FPGA | cs |
dc.subject | fyzika vysokých energií | cs |
dc.subject | PMT | cs |
dc.subject | fotonásobič | cs |
dc.subject | LED ovladač | cs |
dc.subject | fyzické vybavení | cs |
dc.subject | PWM | cs |
dc.subject | radiační kalení | cs |
dc.subject.translated | FPGA | en |
dc.subject.translated | high energy physics | en |
dc.subject.translated | PMT | en |
dc.subject.translated | photomultiplier | en |
dc.subject.translated | LED driver | en |
dc.subject.translated | physical instrumentation | en |
dc.subject.translated | PWM | en |
dc.subject.translated | rad-hard | en |
dc.title | Diagnostic Device for Photomultiplier Tubes at ARP ToF Detector | en |
dc.type | conferenceObject | en |
dc.type | konferenční příspěvek | cs |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
Files
Original bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- 09232820.pdf
- Size:
- 2.84 MB
- Format:
- Adobe Portable Document Format
- Description:
- Plný text
License bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: