Cardiac Mathematical Models for Exercise Testing on Treadmill Ergometer

dc.contributor.authorŠtork, Milan
dc.contributor.authorNovák, Jaroslav
dc.contributor.authorBrož, Pavel
dc.contributor.editorPinker, Jiří
dc.date.accessioned2019-10-21T05:33:08Z
dc.date.available2019-10-21T05:33:08Z
dc.date.issued2019
dc.description.abstract-translatedCardiac output (CO) is a key parameter in the assessment of cardiac function, and its measurement is fundamental to the diagnosis, treatment, and prognostic evaluation of all heart diseases. In this paper the linear and nonlinear models for noninvasive estimation of CO are presented. The estimation is based from short examination where parameters of subject were measured up to maximal load and from these parameters the CO and stroke volume (SV) were estimated for evaluation of cardiovascular performance of the subject. This approach was used for group of twenty marathon runners. Linear and nonlinear mathematical models and samples of measuring results are also presented.en
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.identifier.citation2019 International Conference on Applied Electronics: Pilsen, 10th – 11th September 2019, Czech Republic, p. 161-164.en
dc.identifier.isbn978–80–261–0812–2 (Online)
dc.identifier.isbn978–80–261–0813–9 (Print)
dc.identifier.issn1803–7232 (Print)
dc.identifier.issn1805-9597 (Online)
dc.identifier.urihttp://hdl.handle.net/11025/35535
dc.language.isoenen
dc.publisherZápadočeská univerzita v Plznics
dc.rights© Západočeská univerzita v Plznics
dc.rights.accessopenAccessen
dc.subjectvýkon srdcecs
dc.subjectlinearní modelcs
dc.subjectkrychlový modelcs
dc.subjectneinvazivní odhadcs
dc.subjectpříjem kyslíkucs
dc.subjecttepová frekvencecs
dc.subjectobjem tahucs
dc.subject.translatedcardiac outputen
dc.subject.translatedlinear modelen
dc.subject.translatedcubic modelen
dc.subject.translatednon-invasive estimationen
dc.subject.translatedoxygen uptakeen
dc.subject.translatedheart rateen
dc.subject.translatedstrokeen
dc.titleCardiac Mathematical Models for Exercise Testing on Treadmill Ergometeren
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen

Files

Original bundle
Showing 1 - 1 out of 1 results
No Thumbnail Available
Name:
Stork2.pdf
Size:
250 KB
Format:
Adobe Portable Document Format
Description:
Plný text
License bundle
Showing 1 - 1 out of 1 results
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
OPEN License Selector