Determination of systolic, mean and diastolic blood pressures with Dual cuff system is based on physiology
| dc.contributor.author | Jílek, Jiří | |
| dc.contributor.author | Štork, Milan | |
| dc.contributor.editor | Pinker, Jiří | |
| dc.date.accessioned | 2019-10-08T09:14:40Z | |
| dc.date.available | 2019-10-08T09:14:40Z | |
| dc.date.issued | 2016 | |
| dc.description.abstract-translated | Single cuff automatic blood pressure (BP) measurements are subject to errors because the BP values are based on statistical estimation rather than on physiological principles. We developed a dual cuff experimental system that uses an arm cuff and a wrist cuff. The wrist cuff function is similar to auscultation. This study concentrated on the determination of systolic, diastolic and mean BP using the wrist cuff pulse waveforms and the arm cuff pressures. Fifty two BP tests from our database were used to compute blood pressures using the wrist cuff method and the single arm cuff method and the two methods were compared. Mean BP values for both methods were similar but there were important individual differences. The dual cuff method should prove to be more accurate than single cuff methods because it is based on physiological principles. | en |
| dc.format | 4 s. | cs |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | 2016 International Conference on Applied Electronics: Pilsen, 6th – 7th September 2016, Czech Republic, p.117-120. | en |
| dc.identifier.isbn | 978–80–261–0601–2 (Print) | |
| dc.identifier.isbn | 978–80–261–0602–9 (Online) | |
| dc.identifier.issn | 1803–7232 (Print) | |
| dc.identifier.issn | 1805–9597 (Online) | |
| dc.identifier.uri | http://hdl.handle.net/11025/35202 | |
| dc.language.iso | en | en |
| dc.publisher | Západočeská univerzita v Plzni | cs |
| dc.rights | © Západočeská univerzita v Plzni | cs |
| dc.rights.access | openAccess | en |
| dc.subject | zápěstí | cs |
| dc.subject | krevní tlak | cs |
| dc.subject | biomedicínské monitorování | cs |
| dc.subject | měření tlaku | cs |
| dc.subject | software | cs |
| dc.subject | odhad | cs |
| dc.subject.translated | wrist | en |
| dc.subject.translated | blood pressure | en |
| dc.subject.translated | biomedical monitoring | en |
| dc.subject.translated | pressure measurement | en |
| dc.subject.translated | software | en |
| dc.subject.translated | estimation | en |
| dc.title | Determination of systolic, mean and diastolic blood pressures with Dual cuff system is based on physiology | en |
| dc.type | konferenční příspěvek | cs |
| dc.type | conferenceObject | en |
| dc.type.status | Peer-reviewed | en |
| dc.type.version | publishedVersion | en |
Files
Original bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- Jilek.pdf
- Size:
- 254.61 KB
- Format:
- Adobe Portable Document Format
- Description:
- Plný text
License bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: