Effect of the feeder cable and transformer impedance on the mechanical output characteristic of the induction motor
| dc.contributor.author | Král, Ondřej | |
| dc.contributor.editor | Tesařová, Miloslava | |
| dc.date.accessioned | 2017-02-06T10:06:21Z | |
| dc.date.available | 2017-02-06T10:06:21Z | |
| dc.date.issued | 2011 | |
| dc.description.abstract-translated | The first part of this paper deals with the determination of the equivalent circuit parameters of the induction motor, cable and the transformer. The second part of this paper describes the effect of the feeder cable impedance on the mechanical output characteristic of the asynchronous motor. Calculation is performed for the six poles induction motor with the nominal output 20 kW, the feeding transformers with the rated capacity 50 kVA and 630 kVA. Calculation is performed by the MATLAB program. | en |
| dc.format | 5 s. | cs |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | Proceedings of the Intensive Programme 2011. 1st ed. Pilsen: University of West Bohemia. Faculty of electrical engineering. Department of electrical power engineering and environmental engineering, 2011, s. 125-129. ISBN 978-80-261-0010-2. | en |
| dc.identifier.isbn | 978-80-261-0010-2 | |
| dc.identifier.uri | http://home.zcu.cz/~tesarova/IP/Proceedings/Proc_2011/index.htm | |
| dc.identifier.uri | http://hdl.handle.net/11025/22478 | |
| dc.language.iso | en | en |
| dc.publisher | University of West Bohemia. Faculty of electrical engineering. Department of electrical power engineering and environmental engineering | en |
| dc.rights | © University of West Bohemia | en |
| dc.rights.access | openAccess | en |
| dc.subject | ekvivalentní obvod | cs |
| dc.subject | krátký zkušební okruh | cs |
| dc.subject | zkouška naprázdno | cs |
| dc.subject | mechanická výstupní charakteristika | cs |
| dc.subject | operační podmínky | cs |
| dc.subject.translated | equivalent circuit | en |
| dc.subject.translated | short circuit test | en |
| dc.subject.translated | no-load test | en |
| dc.subject.translated | mechanical output characteristic | en |
| dc.subject.translated | operating conditions | en |
| dc.title | Effect of the feeder cable and transformer impedance on the mechanical output characteristic of the induction motor | en |
| dc.type | konferenční příspěvek | cs |
| dc.type | conferenceObject | en |
| dc.type.status | Peer-reviewed | en |
| dc.type.version | publishedVersion | en |
Files
Original bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- Kral.pdf
- Size:
- 382.18 KB
- Format:
- Adobe Portable Document Format
- Description:
- Plný text
License bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: