Wrist cuff method determines diastolic pressure in dual cuff blood pressure system
| dc.contributor.author | Jílek, Jiří | |
| dc.contributor.author | Štork, Milan | |
| dc.date.accessioned | 2019-09-23T12:17:12Z | |
| dc.date.available | 2019-09-23T12:17:12Z | |
| dc.date.issued | 2015 | |
| dc.description.abstract-translated | Single cuff noninvasive blood pressure (BP) measurements performed manually or automatically are subject to errors. We developed an experimental system that uses two cuffs in order to improve accuracy of noninvasive BP measurement. This study concentrated on a novel determination of diastolic BP using wrist cuff pulse waveforms and arm cuff pressures. The method was compared with the oscillometric method using the British Hypertension Society agreement grading system. The resulting grade was B- “good agreement”. The wrist cuff method may prove to be better than single cuff methods because it is based on physiological principles. | en |
| dc.format | 4 s. | cs |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | 2015 International Conference on Applied Electronics: Pilsen, 8th – 9th September 2015, Czech Republic, p.85-88. | en |
| dc.identifier.isbn | 978-80-261-0385-1 (Print) | |
| dc.identifier.isbn | 978-80-261-0386-8 (Online) | |
| dc.identifier.issn | 1803-7232 (Print) | |
| dc.identifier.issn | 1805-9597 (Online) | |
| dc.identifier.uri | http://hdl.handle.net/11025/35098 | |
| dc.language.iso | en | en |
| dc.publisher | Západočeská univerzita v Plzni | cs |
| dc.rights | © University of West Bohemia | en |
| dc.rights.access | openAccess | en |
| dc.subject | manžeta | cs |
| dc.subject | monitoring | cs |
| dc.subject | krevní tlak | cs |
| dc.subject | hypertenze | cs |
| dc.subject | měření tlaku | cs |
| dc.subject | software | cs |
| dc.subject | manuály | cs |
| dc.subject.translated | wrist | en |
| dc.subject.translated | biomedical monitoring | en |
| dc.subject.translated | blood pressure | en |
| dc.subject.translated | hypertension | en |
| dc.subject.translated | pressure measurement | en |
| dc.subject.translated | software | en |
| dc.subject.translated | manuals | en |
| dc.title | Wrist cuff method determines diastolic pressure in dual cuff blood pressure system | en |
| dc.type | konferenční příspěvek | cs |
| dc.type | conferenceObject | en |
| dc.type.status | Peer-reviewed | en |
| dc.type.version | publishedVersion | en |
Files
Original bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- Jilek.pdf
- Size:
- 199.08 KB
- Format:
- Adobe Portable Document Format
- Description:
- Plný text
License bundle
1 - 1 out of 1 results
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: