Verification of Maximum Torque Per Joule Loss Control of a Wound-Rotor Synchronous Machine with Strongly Non-Linear Parameters

dc.contributor.authorHruška, Karel
dc.contributor.authorGlac, Antonín
dc.contributor.authorSuchý, Ondřej
dc.date.accessioned2026-05-05T18:06:03Z
dc.date.available2026-05-05T18:06:03Z
dc.date.issued2025
dc.date.updated2026-05-05T18:06:03Z
dc.description.abstractThis paper presents an analytically derived optimal control strategy for wound-rotor synchronous machines (WRSM) based on minimising the Joule losses in both the stator and rotor windings. The presented control strategy is analysed in terms of analytical derivation, machine current ratios, working regions and constraints. It is experimentally verified on a salient-pole wound-rotor synchronous machine with strongly non-linear equivalent circuit parameters. The verification was performed in two stages: first, considering constant equivalent circuit parameters while assessing strong non-linear behaviour of the machine leading to significant discrepancies in the resulting machine torque. In the second stage, after determination of non-linear machine parameters using measured flux maps, identical control methodology is analysed in terms of variations in ratios between machine currents. Using pre-calculated current ratios the same control methodology is extended for machines with strongly non-linear equivalent circuit parameters and verified in a real environment. The measurement confirms expected machine behaviour in all available control regions achievable by used synchronous motor as well as limits between these control regions. The results of the verification in a real environment show a discrepancy of approximately 5% in measured machine torque in comparison to expected value confirming the validity of the analytically derived approach and introduced modifications for machines with non-linear equivalent circuit parameters.en
dc.format29
dc.identifier.document-number001646410300001
dc.identifier.doi10.3390/electronics14244924
dc.identifier.issn2079-9292
dc.identifier.obd43948462
dc.identifier.orcidHruška, Karel 0000-0001-9002-0029
dc.identifier.orcidGlac, Antonín 0000-0001-9517-5433
dc.identifier.orcidSuchý, Ondřej 0000-0001-9952-0441
dc.identifier.urihttp://hdl.handle.net/11025/67996
dc.language.isoen
dc.project.IDTN02000028
dc.relation.ispartofseriesElectronics
dc.rights.accessA
dc.subjectequivalent circuit parametersen
dc.subjectloss minimizationen
dc.subjectnon-linear systemen
dc.subjectoptimal controlen
dc.subjectwound rotor synchronous motoren
dc.titleVerification of Maximum Torque Per Joule Loss Control of a Wound-Rotor Synchronous Machine with Strongly Non-Linear Parametersen
dc.typeČlánek v databázi WoS (Jimp)
dc.typeČLÁNEK
dc.type.statusPublished Version
local.files.count1*
local.files.size8260122*
local.has.filesyes*
local.identifier.eid2-s2.0-105025963402

Files

Original bundle
Showing 1 - 1 out of 1 results
No Thumbnail Available
Name:
Hruska_electronics-14-04924-v2.pdf
Size:
7.88 MB
Format:
Adobe Portable Document Format
License bundle
Showing 1 - 1 out of 1 results
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections